An inverter’s main job should be
to ensure the optimum energy yield from your solar power system. Multistring
technology was developed by SMA to achieve consistently excellent results
even under complex system conditions.
Especially given the variety of module types that are currently available, unequal
numbers of modules and/or modules facing in different directions in the module
strings, individual and independently operating MPP (maximum power point) controllers
are essential.
The SB 5000TL HC also has an extended input power range to
enable the use of all current cell technologies. With efficiency improved still
further to 96 % and increased input sensitivity, electricity can be fed into
the grid even with minimal sunshine.
Features:
- Suitable for different strings due to separate MPP-Tracking
- Extended input voltage range (125 to 750 V DC)
- transformerless with integrated all-pole sensitive residual
current detection
- Integrated anti-islanding unit (MSD)
- Diagnosis and communication via Powerline Communication,
radio transmission or via data cable (RS232 or RS485)
- Extended temperature range -25 °C to +60 °C
- Enclosure type IP65, suitable for outside installation
- Connection of DC input with waterproof snap cable connectors
- Surge voltage protection with integrated thermally monitored
Varistors
technical details
|
SB5000TL HC |
details |
SB5000TL HC |
details |
|
. |
. |
. |
. |
| Input |
. |
THD
of grid current |
< 4 % |
| Recc. maximum PV-power
(PPV) |
approx. 6000 WP |
|
for
PV-Plants in Germany |
Default
range of AC voltage (UAC) |
198
V – 260 V |
| Max. DC power (PDC, max) |
5300 W |
Possible range of AC voltage |
180 V – 265 V |
| Max. DC voltage (UDC, max) |
750 V |
AC frequency (fAC) |
49.8 Hz – 50.2
Hz |
| PV-voltage range, MPPT (UPV) |
125 V – 750 V |
Possible range of
AC frequency |
45.5 Hz – 54.5
Hz |
| Max. input current (IPV, max) |
2 x 7,5 A |
Short circuit proof |
yes, current control |
| DC voltage ripple (UPP) |
< 10 % |
Connection to utility |
AC screw terminal |
| Max. number of strings (parallel) |
2 |
Efficiency |
. |
| DC disconnection |
Snap cable connectors |
Max. Efficiency |
96 % |
| Thermally monitored varistors |
yes |
Euro-eta |
95 % |
| Ground fault monitoring |
yes |
Enclosure |
. |
| Pole confusion protection |
Short circuit diode |
accord. to DIN EN 60529 |
IP65 |
| Output |
. |
Mechanical Data |
. |
| Max. AC power (PAC, max) |
5000 W |
Width / height / depth in mm |
470 / 490 / 225 |
| Nominal AC power (PAC, nom) |
4600 W |
Weight |
approx . 31 kg |
| Data sheet |
|
|