Skylla Charger 24/48V
Mindestbestellmenge: 0
 825.86EUR
[incl. 19% Tax excl. Shipping] 
shipping wight: 25,00kg
delivery time:
up to 7 days
delivery time:<br>up to 7 days

... oder woanders billiger gesehen, dann ...

Make an offer
No alternate Tag given!
Skylla Charger 24/48V
For a larger presentation
click on the image.

Skylla Charger 24/48V

Perfect chargers for any type of battery

Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail.

Suitable for AC and DC supply (AC-DC and DC-DC operation)

Except for the 3 phase input models, the chargers also accept a DC supply.

Controlled charging

Every TG charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes.

Use of TG chargers as a power supply

As a result of the perfectly stabilized output voltage, a TG charger can be used as a power supply if batteries or large buffer capacitors are not available.

Two outputs to charge 2 battery banks

The TG chargers feature 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery.

To increase battery life: temperature compensation

Every Skylla TG charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting.

Battery voltage sense

In order to compensate for voltage loss due to cable resistance, TG chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.

skylla-ladegeraet-grafik1.gif skylla-ladegeraet-grafik2.gif
Spezifikationen
Skylla 24/30 TG
24/50 TG
24/50 TG
3 phase
24/80 TG 24/100 TG 24/100 TG
3 phase
48/25 TG 48/50 TG
Input voltage (V AC) 230 3 x 400 230 230 3 x 400 230 230
Input voltage range (V AC) 185-264 320-450 185-264 185-264 320-450 185-264 185-264
Input voltage range (V DC) 180-400 x 180-400 180-400 x 180-400 180-400
Frequency (Hz) 45-65
Power factor 1
Charge voltage 'absorption' (V DC) 28,5 28,5 28,5 28,5 28,5 57 57
Charge voltage 'float' (V DC) 26,5 26,5 26,5 26,5 26,5 53 53
Charge current house batt. (A) (2) 30 / 50 50 75 100 100 25 50
Charge current starter batt. (A) 4 4 4 4 4 n.a. n.a.
Charge characteristic IuoUo (three step)
Battery capacity (Ah) 125-500 250-500 400-800 500-1000 500-1000 125-250 250-500
Temperature sensor Ja
Can be used as power supply Ja
Remote alarm Potential free contacts 60V / 1A (1x NO and 1x NC)
Forced cooling Ja
Protection (1) a,b,c,d
Operating temp. range - 20 bis + 50°C
Humidity (non condensing) max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Battery-connection M8 studs
230 V AC-connection screw-clamp 2,5 mm² (AWG 6)
Protection category IP 21
Weight kg (lbs) 5,5 (12.1) 13 (28) 10 (22) 10 (22) 23 (48) 5,5 (12.1) 10 (22)
Abmessungen hxbxt in mm (hxwxd in inches) 365x 250x 147
(14.4x 9.9x 5.8)
365x 250x 257
(14.4x 9.9x 10.1)
365x 250x 257
(14.4x 9.9x 10.1)
365x 250x 257
(14.4x 9.9x 10.1)
515x 260x 265
(20x 10.2x 10.4)
365x 250x 147
(14.4x 9.9x 5.8)
365x 250x 257
(14.4x 9.9x 10.1)
OPTIONS
Temperatursensor Ja
Panel 'Charger Output' Ja
Charger switch Ja
Batterie Alarm Ja
STANDARDS
Safety EN 60335-1, EN 60335-2-29
Emission EN 55014-1, EN 61000-3-2
Immunity EN 55014-2, EN 61000-3-3
  1. Protection
    1. Output short circuit
    2. Battery reverse polarity detection
    3. Battery voltage too high
    4. Temperature too high
  2. 2) Up to 40°C (100°F) ambient

Upgrade

You can upgrade the product by selecting the respective upgrade below.

Skylla Charger:

No alternate Tag given!
Für weitere Informationen, besuchen Sie bitte die Homepage zu diesem Produkt.
No alternate Tag given!
No alternate Tag given!
This product was added to our catalog on Friday, 28. March 2008.
No alternate Tag given!
No alternate Tag given!
 Datasheet in PDF-format
No alternate Tag given!
No alternate Tag given!
No alternate Tag given! Bewertungen Make an offer No alternate Tag given!
No alternate Tag given!
 Warenkorb
No alternate Tag given!
0 Produkte
No alternate Tag given!
 
No alternate Tag given!
No alternate Tag given!
 Zertifikate
No alternate Tag given!





Fair-Shipping-Costs-Siegel



1&1 GreenHosting



Banner
No alternate Tag given!
 Benachrichtigungen
No alternate Tag given!
BenachrichtigungenBenachrichtigen Sie mich über Aktuelles zu diesem Artikel Skylla Charger 24/48V
No alternate Tag given!
 Weiterempfehlen
No alternate Tag given!
 
Empfehlen sie dieses Produkt einem Freund/in weiter.
No alternate Tag given!
 Bewertungen
No alternate Tag given!
Bewertung schreibenBewerten Sie dieses Produkt!
No alternate Tag given!
 Partner
No alternate Tag given!

No alternate Tag given!
 Partner
No alternate Tag given!
Sanitätshaus Sanivit Gesundheitsartikel
No alternate Tag given!

Elektrotechnik Stevens | Johann-Georg-Halske Str. 10 | D-41352 Korschenbroich | Fon +49 (0)2161 9772913 | Fax +49 (0)2161 9772912 | E-Mail info@solar-shop.com

Copyright © 2012 www.pro-umwelt.de
Powered by osCommerce
Umweltenergie-Top100 ÖKOPORTAL - Das Webverzeichnis der Ökobranche Energieliga.de pannelli fotovoltaici
Wind Journal - Windenergie - regenerative Energie


hetzner_slb