Centaur Charger 12 / 24 Volt
Mindestbestellmenge: 0
 238.00EUR
[incl. 19% Tax excl. Shipping] 
shipping wight: 18,00kg
delivery time:
up to 7 days
delivery time:<br>up to 7 days

... oder woanders billiger gesehen, dann ...

Make an offer
No alternate Tag given!
Centaur Charger 12 / 24 Volt
For a larger presentation
click on the image.

Centaur Charger 12 / 24 Volt

Quality without compromise

Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.

Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation)

The chargers will accept a 90-400V DC supply. All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz.

Three outputs that each can supply the full output current

Three isolated outputs to simultaneously charge 3 battery banks Each output is capable to supply the full rated current.

Three stage charging, with temperature compensation

The Centaur charges at bulk rate until the output has reduced to 70 % of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell.

A dip switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries

.

Intelligent, microprocessor controlled version

For the ultimate in battery charging we recommend our Microprocessor Controlled Phoenix range. Important features of the Phoenix Charger range are:

  • adaptive 4-stage charging with variable absorption time, BatterySafe mode and Storage mode
  • VENet: RS-485 interface for remote control, monitoring and computer assisted setting of all parameters
  • battery temperature sensor
  • battery voltage sensor

centaur-ladegeraete-grafik1.gif centaur-ladegeraete-grafik2.gif
Spezifikationen
Centaur Charger 12/20
12/30
24/16
12/40 12/50 12/60
24/30
12/80
24/40
12/100
24/60

24/80
12/200
24/100
Common characteristics Input voltage: 90 – 265 VAC or 90 – 400VDC ; Input frequency: 45 – 65 Hz ; Power factor: 1
Charge voltage ‘absorption’ (V DC) 14,3 / 28,5 (1)
Charge voltage ‘float’ (V DC) 13,5 / 27,0 (1)
Output banks 3
Charge current (A) (2) 20 30 / 16 40 50 60 / 30 80 / 40 100 / 60 80 200 / 100
Total output ammeter Yes
Charge characteristic IUoU (Three stage charging)
Recommended battery capacity (Ah) 80 - 200
120 - 300
45 - 150
160 - 400 200 - 500 240 - 600
120 - 300
320 - 800
160 - 400
400 - 1000
240 - 600

320 - 800
800 - 2000
400 - 1000
Temperature sensor Internal, - 2mV / °C (- 1mV / °F) per cell
Forced cooling Yes, temperature and current controlled fan
Protection Output short circuit, over temperature
Operating temp. range - 20 to 60°C (0 - 140°C)
Ignition protected Yes
Humidity (non condensing) max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Battery-connection M6 studs M8 studs
AC-connection screw-clamp 4 mm² (AWG 6)
Protection category IP 21
Weight kg (lbs) 3,8 (8.4) 5 (11) 12 (26) 16 (35)
Dimensions hxwxd in mm (hxwxd in inches) 355x215x110 (14.0x8.5x4.3) 426x239x135 (16.8x9.4x5.3) 505x255x130 (19.9x10.0x5.2) 505x255x230 (19.9x10.0x9.1)
STANDARDS
Safety EN 60335-1, EN 60335-2-29, UL 1236
Emission EN 55014-1, EN 61000-3-2
Immunity EN 55014-2, EN 61000-3-3
  1. Standard setting. Optimum charge/float voltages for Flooded Lead-acid, Gel-Cell or AGM batteries selectable by dip switch.
  2. Up to 40 °C (100 °F) ambient. Output will reduce to approximately 80 % of nominal at 50 °C (120 °F) and 60 % of nominal at 60 °C (140°F).

Upgrade

You can upgrade the product by selecting the respective upgrade below.

Centaur Charger:

No alternate Tag given!
Für weitere Informationen, besuchen Sie bitte die Homepage zu diesem Produkt.
No alternate Tag given!
No alternate Tag given!
This product was added to our catalog on Friday, 28. March 2008.
No alternate Tag given!
No alternate Tag given!
 Datasheet in PDF-format
No alternate Tag given!
No alternate Tag given!
No alternate Tag given! Bewertungen Make an offer No alternate Tag given!
No alternate Tag given!
 Warenkorb
No alternate Tag given!
0 Produkte
No alternate Tag given!
 Zertifikate
No alternate Tag given!





Fair-Shipping-Costs-Siegel



1&1 GreenHosting



Banner
No alternate Tag given!
 Benachrichtigungen
No alternate Tag given!
BenachrichtigungenBenachrichtigen Sie mich über Aktuelles zu diesem Artikel Centaur Charger 12 / 24 Volt
No alternate Tag given!
 Weiterempfehlen
No alternate Tag given!
 
Empfehlen sie dieses Produkt einem Freund/in weiter.
No alternate Tag given!
 Bewertungen
No alternate Tag given!
Bewertung schreibenBewerten Sie dieses Produkt!
No alternate Tag given!
 Partner
No alternate Tag given!

No alternate Tag given!
 Partner
No alternate Tag given!
Sanitätshaus Sanivit Gesundheitsartikel
No alternate Tag given!

Elektrotechnik Stevens | Johann-Georg-Halske Str. 10 | D-41352 Korschenbroich | Fon +49 (0)2161 9772913 | Fax +49 (0)2161 9772912 | E-Mail info@solar-shop.com

Copyright © 2012 www.pro-umwelt.de
Powered by osCommerce
Umweltenergie-Top100 ÖKOPORTAL - Das Webverzeichnis der Ökobranche Energieliga.de pannelli fotovoltaici
Wind Journal - Windenergie - regenerative Energie


hetzner_slb