Centaur Charger 12 / 24 Volt
Quality without compromise
Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an
adverse environment: heat, humidity and salt air.
Circuit boards are protected with an acrylic coating for maximum corrosion resistance.
Temperature sensors ensure that power components will always operate within specified limits, if needed
by automatic reduction of output current under extreme environmental conditions.
Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation)
The chargers will accept a 90-400V DC supply.
All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether
50 Hz or 60 Hz.
Three outputs that each can supply the full output current
Three isolated outputs to simultaneously charge 3 battery banks
Each output is capable to supply the full rated current.
Three stage charging, with temperature compensation
The Centaur charges at bulk rate until the output has reduced to 70 % of the rated Amps, at which a 4 hour
timer begins. After the timed period the charger switches to float rate.
An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per
cell.
A dip switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM
batteries .
Intelligent, microprocessor controlled version
For the ultimate in battery charging we recommend our Microprocessor Controlled Phoenix range.
Important features of the Phoenix Charger range are:
- adaptive 4-stage charging with variable absorption time, BatterySafe mode and Storage mode
- VENet: RS-485 interface for remote control, monitoring and computer assisted setting of all parameters
- battery temperature sensor
- battery voltage sensor
|
|
| Spezifikationen |
| Centaur Charger |
12/20 |
12/30 24/16 |
12/40 |
12/50 |
12/60 24/30 |
12/80 24/40 |
12/100 24/60 |
24/80 |
12/200 24/100 |
| Common characteristics |
Input voltage: 90 – 265 VAC or 90 – 400VDC ; Input frequency: 45 – 65 Hz ; Power factor: 1 |
| Charge voltage ‘absorption’ (V DC) |
14,3 / 28,5 (1) |
| Charge voltage ‘float’ (V DC) |
13,5 / 27,0 (1) |
| Output banks |
3 |
| Charge current (A) (2) |
20 |
30 / 16 |
40 |
50 |
60 / 30 |
80 / 40 |
100 / 60 |
80 |
200 / 100 |
| Total output ammeter |
Yes |
| Charge characteristic |
IUoU (Three stage charging) |
| Recommended battery capacity (Ah) |
80 - 200 |
120 - 300 45 - 150 |
160 - 400 |
200 - 500 |
240 - 600 120 - 300 |
320 - 800 160 - 400 |
400 - 1000 240 - 600 |
320 - 800 |
800 - 2000 400 - 1000 |
| Temperature sensor |
Internal, - 2mV / °C (- 1mV / °F) per cell |
| Forced cooling |
Yes, temperature and current controlled fan |
| Protection |
Output short circuit, over temperature |
| Operating temp. range |
- 20 to 60°C (0 - 140°C) |
| Ignition protected |
Yes |
| Humidity (non condensing) |
max 95% |
| ENCLOSURE |
| Material & Colour |
aluminium (blue RAL 5012) |
| Battery-connection |
M6 studs |
M8 studs |
| AC-connection |
screw-clamp 4 mm² (AWG 6) |
| Protection category |
IP 21 |
| Weight kg (lbs) |
3,8 (8.4) |
5 (11) |
12 (26) |
16 (35) |
| Dimensions hxwxd in mm (hxwxd in inches) |
355x215x110 (14.0x8.5x4.3) |
426x239x135 (16.8x9.4x5.3) |
505x255x130 (19.9x10.0x5.2) |
505x255x230 (19.9x10.0x9.1) |
| STANDARDS |
| Safety |
EN 60335-1, EN 60335-2-29, UL 1236 |
| Emission |
EN 55014-1, EN 61000-3-2 |
| Immunity |
EN 55014-2, EN 61000-3-3 |
- Standard setting. Optimum charge/float voltages for Flooded Lead-acid, Gel-Cell or AGM batteries selectable by dip switch.
- Up to 40 °C (100 °F) ambient. Output will reduce to approximately 80 % of nominal at 50 °C (120 °F) and 60 % of nominal at 60 °C (140°F).
UpgradeYou can upgrade the product by selecting the respective upgrade below. |
| Centaur Charger: |
|
|